Answer
The VPFlowScope is available in two flow ranges: 0..80mn/sec and 0..150mn/sec. In the table below you will find common pipe diameters and corresponding flow ranges in m3n/hr and SCFM for both VPFlowScope types.
|
|
|
R080
|
R150
|
|
|
Diameter (mm)
|
Insertion depth (mm)
|
Min flow (m3n/hr) (rounded down to 5 m3n/hr)
|
Max flow (m3n/hr) (Rounded down to 5 m3n/hr)
|
Min flow (m3n/hr) (rounded down to 5 m3n/hr)
|
Max flow (m3n/hr) (Rounded down to 5 m3n/hr)
|
Measurement uncertainity
|
|
25
|
20
|
1
|
135
|
DO NOT USE
|
10%
|
|
40
|
35
|
2
|
350
|
DO NOT USE
|
5%
|
|
55
|
50
|
4
|
665
|
25
|
1,247
|
5%
|
|
80
|
40
|
5
|
1,445
|
50
|
2,705
|
2%
|
|
100
|
50
|
10
|
2,260
|
80
|
4,235
|
2%
|
|
160
|
80
|
35
|
5,790
|
215
|
10,855
|
5%
|
|
200
|
100
|
55
|
9,045
|
335
|
16,955
|
5%
|
|
250
|
125
|
85
|
14,135
|
530
|
26,500
|
5%
|
|
|
R080
|
R150
|
|
|
Diameter (mm)
|
Insertion depth (mm)
|
Min flow (CFM) (rounded down to 5 CFM)
|
Max flow (CFM) (rounded down to 5 CFM)
|
Min flow (CFM) (rounded down to 5 CFM)
|
Max flow (CFM) (rounded down to 5 CFM)
|
Measurement uncertainty
|
|
25
|
20
|
0.5
|
80
|
DO NOT USE
|
10%
|
|
40
|
35
|
1
|
205
|
DO NOT USE
|
5%
|
|
55
|
50
|
2
|
390
|
15
|
735
|
5%
|
|
80
|
40
|
3
|
850
|
30
|
1,590
|
2%
|
|
100
|
50
|
6
|
1,330
|
45
|
2,490
|
2%
|
|
160
|
80
|
20
|
3,405
|
125
|
6,390
|
5%
|
|
200
|
100
|
30
|
5,325
|
195
|
9,980
|
5%
|
|
250
|
125
|
50
|
8,320
|
310
|
15,600
|
5%
|