E-library & News, Knowledge, News & articles

Getting optimum results by using our piping table

Create enough straight pipe length

Having a flowmeter is one thing, but installing one is another. It’s very important to select the right installation point for your flowmeter. It’s important to know what to take into account and what needs to be avoided at all costs. The installation point is crucial for correct measurements!

Why the piping table?

Gas flow in pipes follows certain rules, which must be observed for optimal measurement results. A symmetric, fully developed turbulent flow profile is what is needed for accurate flow measurement. Bends, valves and other objects will distort the flow profile, so it is important to install the flow meter with sufficient distance from the distortion.

As a rule of thumb, most manufacturers recommend a minimum of “20 times the pipe diameter” downstream of a 90-degree bend. For some exceptions the upstream length needs to be longer, or it can be shorter. A few common examples in compressed air systems, we have included in our piping table below. The table shows the minimum amount of length, upstream and downstream, depending on the installation.

There are manufacturers that claim a shorter pipe length is adequate for their flow meter technology. But you cannot change the laws of physics and that is why we advise to use the longest pipe length that is available before and after the flow meter.

Gain direct insight into your energy flow and reduce costs with VPInstruments

Soon you’ll not just be measuring air – you’ll be walking on air too because of the results!